Safety First.
Evidence Always.
Material safety and material performance, under stated test methods and boundaries
Before HALOGLAS™ touches the body, safety comes first. HALOGLAS™ safety evaluation is organized around material safety, skin contact, jewelry-related requirements and food-contact requirements where applicable — each mapped to a controlled evidence record.
Safety evaluation overview — material safety, skin contact, jewelry and food-contact requirements. Illustrative visual.
Safety Domain
Testing applies to the specific sample, material, product, test method and conditions identified in each evidence record. Results must not be generalized beyond their stated scope.
Radiological Safety
External exposure / radiological characterization where applicable.
Record pendingSkin Safety
Skin irritation, sensitization and relevant biological-contact testing.
View EvidenceJewelry Safety
Applicable limits and testing for restricted / harmful elements in jewelry-related applications.
View EvidenceFood Contact
Applicable food-contact requirements for products intended for food-contact use.
View EvidenceEvidence applies only to the tested materials, modules and products under the stated conditions. It does not imply universal approval for every application. The radiological domain has no published record yet.
Open Evidence
Every public safety statement should be traceable to a controlled evidence record.
| Tested item | HALOGLAS Energy block — fused far-infrared glass block specimen |
|---|---|
| Method & standard | ISO 10993-10:2021 (6.6) · GB/T 16886.23-2023 / ISO 10993-23:2021 (7.2) |
| Laboratory | Guangdong Detection Center of Microbiology |
| Conditions | Guinea-pig closed-patch sensitization, n=10; rabbit repeated-contact irritation; animal facility in Guangzhou; issued 2026-05-06 |
| Result | Sensitization rate 0% (no sensitization) · cumulative irritation index 0 (very slight) |
| Limitations | Animal-model results on the tested block material. Does not establish human clinical outcomes and does not extend to other materials or products. |
| Allowed wording | Skin sensitization and irritation testing to ISO 10993-10:2021 (6.6) and GB/T 16886.23-2023, on the tested block material. |
| Source report | 2026FM04534R01E (EN) / 2026FM04534R01 (CN) |
| Status | Published / AU: Not Applicable |
| Tested item | Far-infrared energy glass material — light-yellow glass, cooking-ware specimen |
|---|---|
| Method & standard | GB 4806.5-2016 · GB 31604.34-2016 / GB 31604.24-2016 |
| Laboratory | SGS-CSTC Standards Technical Services (Tianjin) Co., Ltd. |
| Conditions | 98 °C, 120 min, 4% acetic acid; sensory + lead/cadmium migration |
| Result | Lead migration <0.1 mg/L (limit 0.5) · cadmium <0.01 mg/L (limit 0.05) · sensory compliant |
| Limitations | Applies only to the tested specimen under the stated 98 °C / 120 min / 4% acetic acid conditions. Vessel shape and use conditions change the applicable classification — one report does not cover every food-contact scenario. |
| Allowed wording | Tested to applicable food-contact standards (GB 4806.5-2016) for the tested specimen and stated conditions. |
| Source report | TSNHL26000522502 (SGS No. TJHL2602001052CW) · 2026-02-10 |
| Status | Published / AU: Not Applicable |
| Tested item | HALOGLAS Energy pearl — light-yellow glass bead |
|---|---|
| Method & standard | GB 28480-2012 (4.1 nickel release · 4.2.1 total heavy elements) · GB/T 19719-2005 |
| Laboratory | Centre Testing International (Shanghai) Co., Ltd. |
| Conditions | 168 h artificial-sweat immersion; ICP-OES / UV-Vis |
| Result | Nickel release N.D. <0.05 μg/cm²/week (limit 0.5) · total Pb / Cd / Hg / As / Cr(VI) all N.D. |
| Limitations | Applies only to the tested energy-pearl bead sample. Not a statement about every HALOGLAS product or configuration. |
| Allowed wording | Tested to applicable jewelry safety standard (GB 28480-2012) for the tested bead sample. |
| Source report | A2260234445103001C · 2026-04-25 |
| Status | Published / AU: Not Applicable |
| Tested item | HALOGLAS™ heat-resistant glass drinkware — men's cup / women's cup |
|---|---|
| Method & standard | GB 17762-2022 — Safety requirements for heat-resistant glassware (alkali resistance · acid resistance) |
| Laboratory | Shanghai Lelang Testing Technology Co., Ltd. |
| Conditions | Alkali-resistance and acid-resistance testing per GB 17762-2022; tested Jan 2026 |
| Result | Men's cup alkali resistance A2 · women's cup alkali resistance A2 · women's cup acid resistance H3 |
| Limitations | Applies only to the tested drinkware samples and only to the tested resistance items (alkali / acid). Not a statement about thermal-shock or every use condition. |
| Allowed wording | Tested to GB 17762-2022 heat-resistant glassware safety requirements for the tested drinkware. |
| Source report | AL26010000801 · AL26010000901 · AL26010047101 |
| Status | Published / AU: Not Applicable |
Unique identifier, level L1–L5. Public route: /evidence/{id}.
Material, module, product, body part / contact site, sample form, test specimen.
Test method, standard, applicable regulation, version / year.
Laboratory, laboratory accreditation, equipment, test conditions, sample conditions, test date, report number.
Numerical value + unit + applicable limit / statistic.
The authorized statement that this record can support — and nothing beyond it.
Scenarios the record does not cover. Always displayed with the result.
Open original report — the source document behind the record.
Each evidence record follows a fixed, controlled format. The fields above are always shown.
Current Safety Evidence
Summaries are for navigation only. Full details appear in each evidence record.
| Domain | Tested item | Standard | Status | Key results | Laboratory | Report No. | Level |
|---|---|---|---|---|---|---|---|
| Skin Safety | Far-infrared energy block | ISO 10993-10:2021 · GB/T 16886.23-2023 | No sensitization | 0% sensitization; irritation index 0 | Guangdong Detection Center of Microbiology | 2026FM04534R01E | L1 |
| Food Contact (CN) | Far-infrared energy glass material | GB 4806.5-2016 | Compliant | Pb <0.1 mg/L; Cd <0.01 mg/L | SGS (Tianjin) | TSNHL26000522502 | L1 |
| Food Contact (US) | HALOGLAS energy glass material | US FDA CPG 545.400 / 545.450 | Compliant | Pb <0.05 μg/mL; Cd <0.01 μg/mL | SGS (Tianjin) | TSNHL26000834002 | L1 |
| Food Contact (EU) | HALOGLAS energy glass material | LFGB §30 · DIN 51032:2017 · Reg. 1935/2004 | Compliant | Pb <0.1 mg/dm²; Cd <0.01; Co <0.01 | SGS (Tianjin) | TSNHL26000834202 | L1 |
| Jewelry Safety | Energy glass bead | GB 28480-2012 | Compliant | Ni release N.D.; Pb/Cd/Hg/As/Cr(VI) N.D. | CTI (Shanghai) | A2260234445103001C | L1 |
| Heat-resistant Glass | Men's cup | GB 17762-2022 (alkali) | Compliant | Alkali resistance A2 | Lelangtek (Shanghai) | AL26010000801 | L1 |
| Heat-resistant Glass | Women's cup | GB 17762-2022 (alkali) | Compliant | Alkali resistance A2 | Lelangtek (Shanghai) | AL26010000901 | L1 |
| Heat-resistant Glass | Women's cup | GB 17762-2022 (acid) | Compliant | Acid resistance H3 | Lelangtek (Shanghai) | AL26010047101 | L1 |
Rows above are report-verified. Each row corresponds to one source report; report numbers and values are taken directly from the reports. Food-contact rows apply to the tested specimen and stated conditions only.
Skin-contact safety testing — closed-patch sensitization and repeated-exposure irritation, reported as result cards. Source: laboratory report.
Evidence Level System
Evidence levels describe the role of each record within the HALOGLAS™ evidence architecture. Higher levels do not mean ‘better’ evidence.
Safety
Safety, toxicology, radiological, skin, jewelry and food-contact evidence where applicable.
Performance
Material or functional performance measurements.
Human Wear
Human-use / human-wear observations and controlled studies, limited to the tested product and body area.
Research
Exploratory scientific research.
Adjacent
Applications or evidence outside the core intended use. Held outside the core intended use and not used to support HALOGLAS™ product claims.
How We Report Evidence
Traceable
Every public evidence statement should connect to an Evidence ID.
Specific
Results apply to the tested material, sample, product, method and conditions.
Numerical
Where available, numerical results are shown with units and applicable limits.
Limited
Limitations are displayed together with the result.
No Overclaiming
Testing results are not automatically converted into therapeutic, medical or universal safety claims.
Material Performance. Defined by Data.
HALOGLAS™ material performance is characterized through measurable parameters, defined test methods and stated operating boundaries.
FIR / Thermal Emission
Normal-hemispherical total emissivity measured at 40 °C under defined sample and method conditions.
Request Report
Antimicrobial Performance
Photocatalytic antibacterial rate against specified strains, under the stated method (GB/T 30706-2014).
Request Report
Piezoelectric Response
Weak piezoelectric characteristics — no published evidence record yet.
Evidence pending
Thermoelectric Response
Thermoelectric response — no published evidence record yet.
Evidence pending