Safety&Performance

HALOGLAS™ — Safety & Performance Evidence (Preview V3)
Evidence & Standards · Technical audiences

Safety First.
Evidence Always.

Material safety and material performance, under stated test methods and boundaries

Before HALOGLAS™ touches the body, safety comes first. HALOGLAS™ safety evaluation is organized around material safety, skin contact, jewelry-related requirements and food-contact requirements where applicable — each mapped to a controlled evidence record.

HALOGLAS safety evaluation overview

Safety evaluation overview — material safety, skin contact, jewelry and food-contact requirements. Illustrative visual.

01Traceable to an Evidence ID
02Specific to sample, method and conditions
03Numerical, with units and limits
04Limitations shown with the result
Safety evaluation

Safety Domain

Testing applies to the specific sample, material, product, test method and conditions identified in each evidence record. Results must not be generalized beyond their stated scope.

Radiological Safety

External exposure / radiological characterization where applicable.

Record pending

Skin Safety

Skin irritation, sensitization and relevant biological-contact testing.

View Evidence

Jewelry Safety

Applicable limits and testing for restricted / harmful elements in jewelry-related applications.

View Evidence

Food Contact

Applicable food-contact requirements for products intended for food-contact use.

View Evidence

Evidence applies only to the tested materials, modules and products under the stated conditions. It does not imply universal approval for every application. The radiological domain has no published record yet.

Open evidence

Open Evidence

Every public safety statement should be traceable to a controlled evidence record.

HG-EV-SKIN-001L1 · Safety
Tested item HALOGLAS Energy block — fused far-infrared glass block specimen
Method & standard ISO 10993-10:2021 (6.6) · GB/T 16886.23-2023 / ISO 10993-23:2021 (7.2)
Laboratory Guangdong Detection Center of Microbiology
Conditions Guinea-pig closed-patch sensitization, n=10; rabbit repeated-contact irritation; animal facility in Guangzhou; issued 2026-05-06
Result Sensitization rate 0% (no sensitization) · cumulative irritation index 0 (very slight)
Limitations Animal-model results on the tested block material. Does not establish human clinical outcomes and does not extend to other materials or products.
Allowed wording Skin sensitization and irritation testing to ISO 10993-10:2021 (6.6) and GB/T 16886.23-2023, on the tested block material.
Source report 2026FM04534R01E (EN) / 2026FM04534R01 (CN)
Status Published / AU: Not Applicable
Full detail in the source report.Download Report
HG-EV-FC-CN-001L1 · Safety
Tested item Far-infrared energy glass material — light-yellow glass, cooking-ware specimen
Method & standard GB 4806.5-2016 · GB 31604.34-2016 / GB 31604.24-2016
Laboratory SGS-CSTC Standards Technical Services (Tianjin) Co., Ltd.
Conditions 98 °C, 120 min, 4% acetic acid; sensory + lead/cadmium migration
Result Lead migration <0.1 mg/L (limit 0.5) · cadmium <0.01 mg/L (limit 0.05) · sensory compliant
Limitations Applies only to the tested specimen under the stated 98 °C / 120 min / 4% acetic acid conditions. Vessel shape and use conditions change the applicable classification — one report does not cover every food-contact scenario.
Allowed wording Tested to applicable food-contact standards (GB 4806.5-2016) for the tested specimen and stated conditions.
Source report TSNHL26000522502 (SGS No. TJHL2602001052CW) · 2026-02-10
Status Published / AU: Not Applicable
Full detail in the source report.Download Report
HG-EV-JW-001L1 · Safety
Tested item HALOGLAS Energy pearl — light-yellow glass bead
Method & standard GB 28480-2012 (4.1 nickel release · 4.2.1 total heavy elements) · GB/T 19719-2005
Laboratory Centre Testing International (Shanghai) Co., Ltd.
Conditions 168 h artificial-sweat immersion; ICP-OES / UV-Vis
Result Nickel release N.D. <0.05 μg/cm²/week (limit 0.5) · total Pb / Cd / Hg / As / Cr(VI) all N.D.
Limitations Applies only to the tested energy-pearl bead sample. Not a statement about every HALOGLAS product or configuration.
Allowed wording Tested to applicable jewelry safety standard (GB 28480-2012) for the tested bead sample.
Source report A2260234445103001C · 2026-04-25
Status Published / AU: Not Applicable
Full detail in the source report.Request Report
HG-EV-HR-001L1 · Safety
Tested item HALOGLAS™ heat-resistant glass drinkware — men's cup / women's cup
Method & standard GB 17762-2022 — Safety requirements for heat-resistant glassware (alkali resistance · acid resistance)
Laboratory Shanghai Lelang Testing Technology Co., Ltd.
Conditions Alkali-resistance and acid-resistance testing per GB 17762-2022; tested Jan 2026
Result Men's cup alkali resistance A2 · women's cup alkali resistance A2 · women's cup acid resistance H3
Limitations Applies only to the tested drinkware samples and only to the tested resistance items (alkali / acid). Not a statement about thermal-shock or every use condition.
Allowed wording Tested to GB 17762-2022 heat-resistant glassware safety requirements for the tested drinkware.
Source report AL26010000801 · AL26010000901 · AL26010047101
Status Published / AU: Not Applicable
Full detail in the source reports.Download Report
Evidence ID

Unique identifier, level L1–L5. Public route: /evidence/{id}.

What Was Tested

Material, module, product, body part / contact site, sample form, test specimen.

Method & Standard

Test method, standard, applicable regulation, version / year.

Laboratory & Conditions

Laboratory, laboratory accreditation, equipment, test conditions, sample conditions, test date, report number.

Result

Numerical value + unit + applicable limit / statistic.

Allowed Wording

The authorized statement that this record can support — and nothing beyond it.

Limitations

Scenarios the record does not cover. Always displayed with the result.

Source

Open original report — the source document behind the record.

Evidence record structure

Each evidence record follows a fixed, controlled format. The fields above are always shown.

Current

Current Safety Evidence

Summaries are for navigation only. Full details appear in each evidence record.

Domain Tested item Standard Status Key results Laboratory Report No. Level
Skin Safety Far-infrared energy block ISO 10993-10:2021 · GB/T 16886.23-2023 No sensitization 0% sensitization; irritation index 0 Guangdong Detection Center of Microbiology 2026FM04534R01E L1
Food Contact (CN) Far-infrared energy glass material GB 4806.5-2016 Compliant Pb <0.1 mg/L; Cd <0.01 mg/L SGS (Tianjin) TSNHL26000522502 L1
Food Contact (US) HALOGLAS energy glass material US FDA CPG 545.400 / 545.450 Compliant Pb <0.05 μg/mL; Cd <0.01 μg/mL SGS (Tianjin) TSNHL26000834002 L1
Food Contact (EU) HALOGLAS energy glass material LFGB §30 · DIN 51032:2017 · Reg. 1935/2004 Compliant Pb <0.1 mg/dm²; Cd <0.01; Co <0.01 SGS (Tianjin) TSNHL26000834202 L1
Jewelry Safety Energy glass bead GB 28480-2012 Compliant Ni release N.D.; Pb/Cd/Hg/As/Cr(VI) N.D. CTI (Shanghai) A2260234445103001C L1
Heat-resistant Glass Men's cup GB 17762-2022 (alkali) Compliant Alkali resistance A2 Lelangtek (Shanghai) AL26010000801 L1
Heat-resistant Glass Women's cup GB 17762-2022 (alkali) Compliant Alkali resistance A2 Lelangtek (Shanghai) AL26010000901 L1
Heat-resistant Glass Women's cup GB 17762-2022 (acid) Compliant Acid resistance H3 Lelangtek (Shanghai) AL26010047101 L1

Rows above are report-verified. Each row corresponds to one source report; report numbers and values are taken directly from the reports. Food-contact rows apply to the tested specimen and stated conditions only.

Skin-contact safety testing — sensitization and irritation results

Skin-contact safety testing — closed-patch sensitization and repeated-exposure irritation, reported as result cards. Source: laboratory report.

Framework

Evidence Level System

Evidence levels describe the role of each record within the HALOGLAS™ evidence architecture. Higher levels do not mean ‘better’ evidence.

L1

Safety

Safety, toxicology, radiological, skin, jewelry and food-contact evidence where applicable.

L2

Performance

Material or functional performance measurements.

L3

Human Wear

Human-use / human-wear observations and controlled studies, limited to the tested product and body area.

L4

Research

Exploratory scientific research.

L5

Adjacent

Applications or evidence outside the core intended use. Held outside the core intended use and not used to support HALOGLAS™ product claims.

Method

How We Report Evidence

01

Traceable

Every public evidence statement should connect to an Evidence ID.

02

Specific

Results apply to the tested material, sample, product, method and conditions.

03

Numerical

Where available, numerical results are shown with units and applicable limits.

04

Limited

Limitations are displayed together with the result.

05

No Overclaiming

Testing results are not automatically converted into therapeutic, medical or universal safety claims.

Performance evidence

Material Performance. Defined by Data.

HALOGLAS™ material performance is characterized through measurable parameters, defined test methods and stated operating boundaries.

Infrared thermal characterization

FIR / Thermal Emission

Normal-hemispherical total emissivity measured at 40 °C under defined sample and method conditions.

Request Report
HALOGLAS material sample

Antimicrobial Performance

Photocatalytic antibacterial rate against specified strains, under the stated method (GB/T 30706-2014).

Request Report
HALOGLAS material on a laboratory bench

Piezoelectric Response

Weak piezoelectric characteristics — no published evidence record yet.

Evidence pending
HALOGLAS beacon worn on the wrist

Thermoelectric Response

Thermoelectric response — no published evidence record yet.

Evidence pending
Shopping Cart
Scroll to Top